Please use this identifier to cite or link to this item: https://cuir.car.chula.ac.th/handle/123456789/61688
Title: Gold nanoparticle core–europium(III) chelate fluorophore-doped silica shell hybrid nanocomposites for the lateral flow immunoassay of human thyroid stimulating hormone with a dual signal readout
Authors: Pattarachaya Preechakasedkit
Osada, Kota
Katayama, Yuta
Nipapan Ruecha
Suzuki, Koji
Orawon Chailapakul
Citterio, Daniel
Email: No information provided
No information provided
No information provided
No information provided
No information provided
Orawon.C@Chula.ac.th
No information provided
Other author: Chulalongkorn University. Faculty of Science
Issue Date: 21-Jan-2018
Publisher: Royal Society of Chemistry
Citation: Analyst, Vol.143, Issue 2, (January 21, 2018) , p. 564-570.
Abstract: Hybrid nanocomposite particles composed of a gold core coated with a europium(III)-chelate fluorophore-doped silica shell (AuNPs@SiO2–Eu3+) have been synthesized and applied as antibody labels in lateral flow immunoassay (LFIA) devices for the determination of human thyroid stimulating hormone (hTSH). Labeling of monoclonal anti-hTSH antibodies with AuNPs@SiO2–Eu3+ nanocomposites allows for both colorimetric and fluorometric observation of assay results on LFIA devices, relying on visible light absorption due to the localized surface plasmon resonance of the Au-core and the fluorescence emission of the Eu(III)-chelate-modified shell under UV hand lamp irradiation (365 nm), respectively. The possibility for a dual signal readout provides an attractive alternative for LFIAs: instantaneous naked eye observation of the AuNP colorimetric signal as in conventional LFIAs for hypothyroidism detection, and more sensitive fluorescence detection to assess hyperthyroidism. The limits of detection (LOD) for naked eye observation of LFIA devices are 5 μIU mL−1 and 0.1 μIU mL−1 for the colorimetric and fluorimetric detection, respectively. Using the fluorescence detection scheme in combination with a smartphone and digital color analysis, a quantitative linear relationship between the red intensity and the logarithmic concentration of hTSH was observed (R2 = 0.988) with an LOD of 0.02 μIU mL−1. Finally, LFIA devices were effectively applied for detecting hTSH in spiked diluted human serum with recovery values between 100–116%.
URI: http://cuir.car.chula.ac.th/handle/123456789/61688
URI: https://pubs.rsc.org/en/content/articlelanding/2018/AN/C7AN01799E#!divAbstract
http://doi.org/10.1039/C7AN01799E
ISSN: 0003-2654
metadata.dc.identifier.DOI: 10.1039/C7AN01799E
Type: Article
Appears in Collections:Foreign Journal Article

Files in This Item:
File Description SizeFormat 
html_submission_64659.htmlLink to Fulltext2.83 kBHTMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.