Please use this identifier to cite or link to this item: https://cuir.car.chula.ac.th/handle/123456789/62322
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSasimook Chokchai-
dc.contributor.authorSrilert Chotpantarat-
dc.contributor.authorTakashima, Isao-
dc.contributor.authorUchida, Youhei-
dc.contributor.authorWidiatmojo, Arif-
dc.contributor.authorYasukawa, Kasumi-
dc.contributor.authorPunya Charusiri-
dc.contributor.otherChulalongkorn University. Faculty of Science-
dc.date.accessioned2019-06-30T01:04:34Z-
dc.date.available2019-06-30T01:04:34Z-
dc.date.issued2018-09-06-
dc.identifier.citationEnergies. Vol 11, Issue 9, 2356 (2018), 17 pagesen_US
dc.identifier.issn1996-1073-
dc.identifier.urihttp://cuir.car.chula.ac.th/handle/123456789/62322-
dc.description.abstractIn order to reduce electricity consumption, the vertical loop geothermal heat pump (GHP) system coupled with a normal air conditioner was installed in an experimental room in the Parot Racha Building, Chulalongkorn University, Bangkok, Thailand for a comparative, long-term measurement program. The decrease in electricity consumption was approximately 30%. On the basis of the data derived from our measurements, the underground temperature seemed to be consistent and lower than the average outside air temperature, over two years. The underground system consisted mainly of two 50-m-long drilling wells and pipes with a total length of 170 m. The well performance was not examined, but both soil and groundwater aquifer (Bangkok aquifer) at 25 to 50 m. could be utilized for the cooling operation. Moreover, the major controlling factors of electricity consumption were found to be the outside air temperatures and the underground water circulation temperatures. In addition, we considered the geology, underground temperature, and aquifer of Bangkok concluding that almost all Bangkok areas are suitable for GHP installation, except for those where the subsurface temperature is too high compared with the outside air temperatureen_US
dc.language.isoenen_US
dc.publisherMDPI-
dc.relation.urihttps://doi.org/10.3390/en11092356-
dc.relation.urihttps://www.mdpi.com/1996-1073/11/9/2356-
dc.rights© 2018 by the authorsen_US
dc.titleA Pilot Study on Geothermal Heat Pump (GHP) Use for Cooling Operations, and on GHP Site Selection in Tropical Regions Based on a Case Study in Thailanden_US
dc.typeArticleen_US
dc.email.authorNo information provided-
dc.email.authorSrilert.C@Chula.ac.th-
dc.email.authorNo information provided-
dc.email.authorNo information provided-
dc.email.authorNo information provided-
dc.email.authorNo information provided-
dc.email.authorpunya.c@chula.ac.th-
dc.subject.keywordBangkok aquiferen_US
dc.subject.keywordelectrical savingen_US
dc.subject.keywordgeothermal heat pump (GHP)en_US
dc.subject.keywordgroundwateren_US
dc.subject.keywordsubsurface temperatureen_US
dc.subject.keywordtropical regionsen_US
dc.identifier.DOI10.3390/en11092356-
Appears in Collections:Foreign Journal Article

Files in This Item:
File Description SizeFormat 
html_submission_65144.htmlLink to fulltext2.75 kBHTMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.